APISTE Panel Cooling Unit –Outdoor Lateral-mount Type
ENC-A510HD/A520HD
ENC-AR510HD/AR520HD
ENC-A1010HD/A1020HD
ENC-AR1010HD/AR1020HD
ENC-A1610HD/A1620HD
ENC-AR1610HD/AR1620HD
ENC-A2900HD
ENC-AR2900HD
ENC-A510HD/A520HD
ENC-A510HD
ENC-A520HD
ENC-AR510HD/AR520HD
ENC-AR510HD
ENC-AR520HD
ENC-A1010HD/A1020HD
ENC-A1010HD
ENC-A1020HD
ENC-AR1010HD/AR1020HD
ENC-AR1010HD
ENC-AR1020HD
ENC-A1610HD/A1620HD
ENC-A1610HD
ENC-A1620HD
ENC-AR1610HD/AR1620HD
ENC-AR1610HD
ENC-AR1620HD
ENC-A2900HD
ENC-A2900HD
ENC-AR2900HD
ENC-AR2900HD
Model
ENC-A510HD
ENC-A520HD
Type
Outdoors lateral-mount type
Cooling scheme
Compressor
Cooling capacity (W)
300/380(50/60Hz)
Power supply (50/60Hz)
1 phase 100VAC±10%
1 phase 200VAC±10%
Current consumption (A)(MAX)
3.9/3.8
2.0/1.7
Starting current (A)
7.4/7.7
4.0/4.2
Power consumption (W)(MAX)
330/370
330/320
Allowable ambient temperature (ºC)
0 to 50
Allowable ambient humidity (%)
10 to 85 (No condensation)
Operation control scheme
Microcomputer-based automatic control
Refrigerant
R-134a (A kind of freon that is not prohibited)
Temperature setting range (ºC)
25 to 45
Number of fans
1
Outer dimensions (mm)
H:300×W:115×D:530
Weight(kg)
15
Model
ENC-AR510HD
ENC-AR520HD
Type
Outdoors lateral-mount type
Cooling scheme
Compressor
Cooling capacity (W)
450/550(50/60Hz)
Power supply (50/60Hz)
1 phase 100VAC±10%
1 phase 200VAC±10%
Current consumption (A)(MAX)
3.9/4.2
2.1/1.9
Starting current (A)
7.4/7.7
4.9/4.4
Power consumption (W)(MAX)
365/410
365/360
Allowable ambient temperature (ºC)
-5 to 50
Allowable ambient humidity (%)
10 to 85 (No condensation)
Operation control scheme
Microcomputer-based automatic control
Refrigerant
R-134a (A kind of freon that is not prohibited)
Temperature setting range (ºC)
25 to 45
Number of fans
2
Outer dimensions (mm)
H:450×W:350×D:200
Weight(kg)
17
Model
ENC-A1010HD
ENC-A1020HD
Type
Outdoors lateral-mount type
Cooling scheme
Compressor
Cooling capacity (W)
900/1000 (50/60Hz)
Power supply (50/60Hz)
1 phase 100VAC±10%
1 phase 200VAC±10%
Current consumption (A)(MAX)
6.5/6.3
3.1/3.0
Starting current (A)
15.6/14.7
7.5/7.1
Power consumption (W)(MAX)
595/615
570/590
Allowable ambient temperature (ºC)
-5 to 50
Allowable ambient humidity (%)
10 to 85 (No condensation)
Operation control scheme
Microcomputer-based automatic control
Refrigerant
R-134a
Temperature setting range (ºC)
25 to 45
Number of fans
2
Output
Output of operation & alarm(250V 2A)
Display
LED Temperature/Error Run
Noise immunity
Level 4 in the fast transient/Burst immunity test
Noise (dB)
Approx. 64/66
Vibration resistance
Vibration frequency : 5Hz ; a double amplitude of 20mm
Outer dimensions (mm)
H730×W300×D280
Weight(kg)
26
Model
ENC-AR1010HD
ENC-AR1020HD
Type
Outdoors lateral-mount type
Cooling scheme
Compressor
Cooling capacity (W)
900/1000 (50/60Hz)
Power supply (50/60Hz)
1 phase 100VAC±10%
1 phase 200VAC±10%
Current consumption (A)(MAX)
6.5/6.3
3.1/3.0
Starting current (A)
15.6/14.7
7.5/7.1
Power consumption (W)(MAX)
595/615
570/590
Allowable ambient temperature (ºC)
-5 to 50
Allowable ambient humidity (%)
10 to 85 (No condensation)
Operation control scheme
Microcomputer-based automatic control
Refrigerant
R-134a
Temperature setting range (ºC)
25 to 45
Number of fans
2
Output
Output of operation & alarm(250V 2A)
Display
LED Temperature/Error Run
Noise immunity
Level 4 in the fast transient/Burst immunity test
Noise (dB)
Approx. 64/66
Vibration resistance
Vibration frequency : 5Hz ; a double amplitude of 20mm
Outer dimensions (mm)
H730×W300×D280
Weight(kg)
26
Model
ENC-A1610HD
ENC-A1620HD
Type
Outdoors lateral-mount type
Cooling scheme
Compressor
Cooling capacity (W)
1450/1600 (50/60Hz)
Power supply (50/60Hz)
1 phase 100VAC±10%
1 phase 200VAC±10%
Current consumption (A)(MAX)
8.5/8.8
4.3/4.5
Starting current (A)
22.3/20.5
13/12
Power consumption (W)(MAX)
740/830
780/840
Allowable ambient temperature (ºC)
-5 to 50
Allowable ambient humidity (%)
10 to 85 (No condensation)
Operation control scheme
Microcomputer-based automatic control
Refrigerant
R-407c (A kind of freon that is not prohibited)
Temperature setting range (ºC)
25 to 45
Number of fans
4
Outer dimensions (mm)
H:1000×W:400×D:260
Weight(kg)
42
Model
ENC-AR1610HD
ENC-AR1620HD
Type
Outdoors lateral-mount type
Cooling scheme
Compressor
Cooling capacity (W)
1450/1600 (50/60Hz)
Power supply (50/60Hz)
1 phase 100VAC±10%
1 phase 200VAC±10%
Current consumption (A)(MAX)
8.5/8.8
4.3/4.5
Starting current (A)
22.3/20.5
13/12
Power consumption (W)(MAX)
740/830
780/840
Allowable ambient temperature (ºC)
-5 to 55
Allowable ambient humidity (%)
10 to 85 (No condensation)
Operation control scheme
Microcomputer-based automatic control
Refrigerant
R-407c (A kind of freon that is not prohibited)
Temperature setting range (ºC)
25 to 45
Number of fans
4
Outer dimensions (mm)
H:1000×W:400×D:260
Weight(kg)
42
Model
ENC-A2900HD
Type
Outdoors lateral-mount type
Cooling scheme
Compressor
Cooling capacity (W)
2600/2900(50/60Hz)
Power supply (50/60Hz)
1 phase 200VAC±10%
Current consumption (A)(MAX)
9.3/9.4
Starting current (A)
33/30
Power consumption (W)(MAX)
1650/1850
Allowable ambient temperature (ºC)
-5 to 55
Allowable ambient humidity (%)
10 to 85 (No condensation)
Operation control scheme
Microcomputer-based automatic contorl
Refrigerant
R-134a (A kind of freon that is not prohibited)
Temperature setting range (ºC)
25 to 45
Number of fans
6
Outer dimensions (mm)
H:1380×W:450×D:295
Weight(kg)
60
Model
ENC-AR2900HD
Type
Outdoors lateral-mount type
Cooling scheme
Compressor
Cooling capacity (W)
2600/2900(50/60Hz)
Power supply (50/60Hz)
1 phase 200VAC±10%
Current consumption (A)(MAX)
9.3/9.4
Starting current (A)
33/30
Power consumption (W)(MAX)
1650/1850
Allowable ambient temperature (ºC)
-5 to 55
Allowable ambient humidity (%)
10 to 85 (No condensation)
Operation control scheme
Microcomputer-based automatic contorl
Refrigerant
R-134a (A kind of freon that is not prohibited)
Temperature setting range (ºC)
25 to 45
Number of fans
6
Outer dimensions (mm)
H:1380×W:450×D:295
Weight(kg)
60