APISTE Pump, Blower & Vacuum Systems Heat Exchanger – Temperature Adjustment Unit

Heat Exchanger – Temperature Adjustment Unit

Heat Exchanger – Temperature Adjustment Unit

APISTE Heat Exchanger – Temperature Adjustment Un […]
สนใจสินค้า
Type
Model :
Heat Exchanger – Temperature Adjustment Unit
Screw diameter for both ends:
Applicable fluid:
Features

APISTE Heat Exchanger –Temperature Adjustment Unit

ENH-120HD-100/200

ENH-140HD-100/200

ENH-200HD-100/200

ENH-B

ENH-120HD-100/200

ENH-120HD-100

ENH-120HD-200

ENH-140HD-100/200

ENH-140HD-100

ENH-140HD-200

ENH-200HD-100/200

ENH-200HD-100

ENH-200HD-200

ENH-B

ENH-B6045

ENH-B5035

ENH-B4025

ENH-B0520

Model

ENH-120HD-100

ENH-120HD-200

Type

Outdoors heat exchanger

Rated capability

20/25(50/60Hz)

Power supply(50/60Hz)

100VAC±10%

200VAC±10%

Current consumption(A)(MAX)

1.2/1.0

0.48/0.42

Starting current(A)(MAX)

2.6/2.2

0.74/0.64

Power consumption (W) (MAX)

86/80

62/60(50/60Hz)

Allowable ambient temperature (ºC)

60 or less

Allowable ambient humidity (%)

95 or less (outside) 85 or less (inside)

Number of fans

2

Weight(kg)

8

Outer dimensions (mm)

H655×W225×D90

Material of outer case

Stainless(SUS304)

Model

ENH-140HD-100

ENH-140HD-200

Type

Outdoors heat exchanger

Rated capability

40/45(50/60Hz)

Power supply(50/60Hz)

100VAC±10%

200VAC±10%

Current consumption(A)(MAX)

2.4/2.0

0.96/0.84

Starting current(A)(MAX)

5.2/4.4

1.48/1.28

Power consumption (W) (MAX)

172/160

124/120

Allowable ambient temperature (ºC)

60 or less

Allowable ambient humidity (%)

95 or less (outside) 85 or less (inside)

Number of fans

4

Weight(kg)

15

Outer dimensions (mm)

H655×W423×D90

Material of outer case

Stainless(SUS304)

Model

ENH-200HD-100

ENH-200HD-200

Type

Outdoors heat exchanger

Rated capability

100/120(50/60Hz)

Power supply(50/60Hz)

100VAC±10%

200VAC±10%

Current consumption(A)(MAX)

3.4/2.9

1.44/1.26

Starting current(A)(MAX)

7.8/6.6

2.22/1.92

Power consumption (W) (MAX)

258/240

186/180

Allowable ambient temperature (ºC)

60 or less

Allowable ambient humidity (%)

95 or less (outside) 85 or less (inside)

Number of fans

6

Weight(kg)

37

Outer dimensions (mm)

H920×W538×D170

Material of outer case

Stainless(SUS304)

Model

ENH-B6045

ENH-B5035

ENH-B4025

ENH-B0520

Type

Temperature Adjustment Unit ENH-B Series

Detect adjusting level

60ºC

50ºC

40ºC

5ºC

Return level

45ºC

35ºC

25ºC

20ºC

Hysteresis

±5ºC

Output

Alarm output (250V 2.5A)

Outer dimensions (mm)

H70×W40×D25

Weight(g)

70

Application